Mitsubishi Function Blocks

CC-Link Solution Packs are available from the MyMitsubishi Electric website to support their range of PLCs, Inverters and I/O systems.  All packs include GX Developer and GX IEC Developer program examples as well as:

♦ CC-link analog module

♦ Temperature module

♦ High-speed counter module

♦ CC-Link Remote IO module

♦ CC-Link ST-series (Remote IO + Analog IO)

♦ Inverter

♦ Servo (only FX)

 

Solution Packs

1 CCLinkFX_V100.zip GX IEC Developer 7.00 / The project contains 26 CC-LINK function blocks and corresponding program examples for the Melsec FX PLC systems that enable a FX2N-16CCL-M CC-Link master station to control and communicate with CC-Link local stations, remote device stations or remote I/O stations via the CC-Link network.

 

2 CCLinkQ_V320.zip GX IEC Developer 7.01 / Function blocks for CC-Link control and communication (QJ61BT11/QJ61BT11N).

 

3 CCLinkFXInverter_V100.zip GX IEC Developer 7.01 / Function blocks for CC-Link communication operation of FR frequency inverters using a FR-A7NC or FR-A5NC CC-Link plug-in option via a FX2N-16CCL-M CC-Link master module.

 

4 CCLinkFX3UST_V100.zip GX IEC Developer 7.01 / Function blocks for MELSEC ST systems control via CC-Link Message Transmission Protocol, using a FX2N-16CCL-M CC-Link Master block with a FX3U PLC.

 

5 CCLinkFXST_V100.zip GX IEC Developer 7.01 / Function blocks for MELSEC ST systems control via CC-Link Message Transmission Protocol, using a FX2N-16CCL-M CC-Link Master block with a FX1N or a FX2N PLC.

 

6 CCLinkQ_CCLv200_V100.zip GX IEC Developer 7.01 / Function blocks for the CC-Link master (QJ61BT11N) to control and communicate with CC-Link local stations, intelligent stations, remote device stations or remote I/O stations via the CC-Link network when CC-Link protocol version 2.00 is used.

 

7 CCLinkQInverter_CCLv110_V100.zip GX IEC Developer 7.01 / Function blocks for CC-Link communication operation of FR frequency inverters using a FR-A7NC or FR-A5NC CC-Link plug-in option via a QJ61BT11N CC-Link master module using CC-Link protocol version 1.10.

 

8 CCLinkQInverter_CCLv200_V100.zip GX IEC Developer 7.01 / Function blocks for CC-Link communication operation of FR frequency inverters using a FR-A7NC or FR-A5NC CC-Link plug-in option via a QJ61BT11N CC-Link master module using CC-Link protocol version 2.00.

 

9 CCLinkQST_CCLv200_V100.zip GX IEC Developer 7.01 / Function blocks for MELSEC ST systems control via CC-Link version 2.00 protocol & CC-Link Message Transmission Protocol, using a QJ61BT11N CC-Link Master module. This function blocks are mainly used for Error/Status information and parameterizing the slices.

 

10 CCLinkQST_CCLv110_V100.zip GX IEC Developer 7.01 / Function blocks for MELSEC ST systems control via CC-Link version 1.10 protocol & CC-Link Message Transmission Protocol, using a QJ61BT11N CC-Link Master module. This function blocks are mainly used for Error/Status information and parameterizing the slices.

 

11 CCLinkFX_V200.zip GX IEC Developer 7.01 / Function blocks for the CC-Link Master (FX2N-16CCL-M) and the CC-Link remote IO / remote device stations.

 

12 CCLinkQ_CCLv110_V400.zip GX IEC Developer 7.01 / Function blocks for the CC-Link master (QJ61BT11N) to control and communicate with CC-Link local stations, intelligent stations, remote device stations or remote I/O stations via the CC-Link network when CC-Link protocol version 1.10 is used.

 

13 CCLinkQSTDedicated_V210.zip GX IEC Developer 7.01 / Function blocks for MELSEC ST systems control via dedicated instruction using a QJ61BT11N CC-Link Master module. This function blocks are mainly used for Error/Status information and parameterizing the slices.

 

14 CCLinkQ_CCLv110_GD_V1.10 GX Developer / Start up guide with program examples for CC-Link Master and different CC-Link slaves (AJ65BT-64AD, AJ65BT-64DAV/DAI, AJ65BT-64RD3/RD4, AJ65BT-68TD, AJ65BT-D62/D62D(S1), AJ65SBT-62DA, AJ65SBT-64AD, Inverter, Remote I/Os) using CC-Link protocol version 1.10

 

15 CCLinkFX_GD_V100 GX Developer / Start up guide with program examples for CC-Link Master (FX2N-16CCL-M) and different CC-Link slaves (AJ65BT-64AD,AJ65BT-64DAV/DAI, AJ65BT-64RD3/RD4, AJ65BT-68TD, AJ65BT-D62/D62D(S1), AJ65SBT-62DA, AJ65SBT-64AD)

 

16 CCLinkFX_MR_J3_T_V100.zip GX IEC Developer 7.01/ Function blocks for CC-Link control(FX2N-16CCL-M) and communication with Melservo MR-J3-T.

 

17 CCLinkQ_CCLv200_GD_V1.10 GX Developer / Start up guide with program examples for CC-Link Master and different CC-Link slaves (AJ65BT-64AD, AJ65BT-64DAV/DAI, AJ65BT-64RD3/RD4, AJ65BT-68TD, AJ65BT-D62/D62D(S1), AJ65SBT-62DA, AJ65SBT-64AD, Inverter, Remote I/Os) using CC-Link protocol version 2.00

 

18 CCLinkQ_V310 GX IEC Developer 7.00 / Function blocks for CC-Link control and communication (QJ61BT11/QJ61BT11N)

 

19 GOT1000 - GT15 CC-Link connection Start-up for GT15 HMIs and System Q PLC connection via CC-Link network

 

20 GOT1000 - GT15 Station Switching GT Designer 2 sample project for GT15 HMIs explaining how to take advantage of Ethernet, CC-Link or Melsecnet networks in the GT15

 

21 StartUp Guide Safety PLC V1 00.zip Start up manual for getting an Safety PLC + Safety CC-Link Master + Safety CC-Link slave to work.